.:: ACURA Global ::.

AcuTag UHF Titan General

The AcuTag UHF Titan General offers a great performance in metal and non metal, and is ideal for severe environments with exposition to high temperatures, impacts and chemical products.

Technical specifications


* The reading distance may vary according to tag, antenna, cable and environment of use of the reader.
** Respecting specifications.

Test Data


Mechanical tests

Tests Criteria Description
Vibration IEC60068-2-6/64 Tag submitted to vibrations of many frequencies and intensities
Smashing 50 Kg Smashing of tags with 50 Kg at 1m/s - 500 times
Object drop 1 Kg object and 1.5 m drop Drop of a 1 Kg iron sphere at 1.5 m over the tag
Pressurized water jet Jensen equipment Withstands up to 57 bar - 50 times

Temperature tests

Tests Criteria Description
Max temperature 200°C Withstands 200°C for 6 hs
Thermal cycle -45°C <-> 150°C Withstands 500 -45°C to 150°C cycles

Humidity tests

Tests Criteria Description
Humidity chamber 85°C / 85% RH Withstood 85/85 por 168 hs
Boiling water 100°C Tag immersed in boiling water for 48 hours

Chemical Tests

Tests Criteria Description
Acid substance 5% sulphuric acid Tag immersed for 24 hours
Alcaline substance 5% sodium hydroxide Tag immersed for 24 hours
Salt water IEC60060-2-11 Tag immersed for 24 hours
Kerosene 99,9% Tag immersed for 24 hours
Diesel 99,9% Tag immersed for 24 hours
Gasoline 99,9% Tag immersed for 24 hours
Ehtanol 99,9% Tag immersed for 24 hours
Methanol 99,9% Tag immersed for 24 hours
Medicinal enzime STERIS Tag immersed for 24 hours

Product Code:

Without adhesive: 500.524 | With adhesive: 500.470